Home Products News Contact Us
Home > Supports > Generator Sets > Precautions for Outdoor Use of Diesel Generator Sets

Precautions for Outdoor Use of Diesel Generator Sets

Nov. 13, 2024

Diesel generator sets can be used outdoors as backup power sources, playing a significant role in power repairs and outdoor engineering projects. However, in this warm spring season, the air is filled with pollen, fluff, and other substances, which is not only unfriendly to people who are prone to allergies, but also unfriendly to outdoor diesel generators. Especially for units with damaged air filters or no air filters installed, pollen and impurities in the air can directly enter the generator, leading to the following consequences:


diesel generator price


1. Increased fuel consumption

 

Impurities entering the piston ring groove will intensify the wear between the piston rings and the piston, and will also form carbon deposits with engine oil in the piston ring groove, causing the piston rings to bond, get stuck, and lose their oil spreading and scraping effects, resulting in increased oil consumption.

 

2. Unit cylinder pulling

 

During the air compression process, impurities in the air will enter between the piston and cylinder wall, exacerbating the wear of the piston and cylinder wall. If the particle diameter is too large, it may cause cylinder failure in the unit.

 

3. Formation of carbon deposits

 

Engine oil vapor, gum in fuel, and combustion products are all searching for places to attach and form carbon deposits, while impurities in the air can act as crystal nuclei for carbon deposits, allowing them to form faster.

 

4. Power reduction

 

Impurity particles flowing at high speed through the valve and valve seat ring can scratch the sealing surface, reduce the sealing performance of the valve, lead to a decrease in the compression performance of the diesel generator, and ultimately result in a decrease in generator power.

 

The function of an air filter is to filter out dust and impurities in the air, and send clean air or a combustible mixture of air and fuel into the combustion chamber to reduce wear between the piston and the cylinder liner, between the piston group, and between the valve group. Therefore, diesel generators used outdoors must install an air filter and pay attention to regularly replacing the air filter element. Generally, Top Power recommends replacing the air filter every 600-900 hours. If the environment is harsh, the replacement time should be shortened.

 

Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us