Diesel generator sets are widely used in various fields such as industry, agricultural breeding, medical care, military, and schools. For users, it is becoming increasingly important to understand the knowledge and application of diesel generators. Today, the editor will share two pieces of knowledge with you. One is the usage instructions for generator sets at different altitudes and temperatures, and the other is the functions of the generator coupling.


shangchai diesel generator


The main components of a diesel generator set are the engine and the generator. Normally, we need an excellent diesel generator set to meet our power needs. Under different environmental temperatures and high - altitude conditions, what is the correct way to use it? The editor has summarized the following points for you:

 

Environmental temperature and altitude

The engine can operate under the following conditions without power adjustment:

For an engine with a rotational speed of 1800 r/min, the altitude is below 1525 m (5000 ft) and the environmental temperature is below 40°C (104°F).

For an engine with a rotational speed of 1500 r/min, the altitude is below 1525 m (5000 ft) and the environmental temperature is below 40°C (104°F).

 

When the generator operates beyond the above - mentioned conditions:

When the altitude is higher than 1525 m (5000 ft), for every 300 m (1000 ft) increase in altitude, the power should be reduced by 4%.

When the environmental temperature is higher than 40°C (104°F), for every 11°C increase in temperature, the power should be reduced by 2% (for every 10°F increase, the power should be reduced by 1%).

The above are the usage instructions for the Shangchai generator set at different altitudes and environmental temperatures, provided for your reference.

 

What are the functions of the generator coupling?

1.Connection device: The coupling is a connecting device used to connect power - output mechanisms such as engines and driven mechanisms. It connects working components on different working planes so that they can work together.

2.Power transmission component: When two different mechanisms are connected by a coupling, the driving mechanism drives the driven mechanism to work under the fixation of the coupling, transmitting torque and power. Some couplings can not only transmit torque and power but also have different degrees of axial, radial, and angular compensation capabilities.

3.Shock - absorption and buffering: The coupling has the functions of shock - absorption and buffering.

 

The functions of the coupling are roughly the above three types. According to their functions, couplings can be roughly divided into three categories: rigid couplings, flexible couplings, and safety couplings. Rigid couplings can only transmit motion and torque. Flexible couplings can not only transmit motion and torque but also have different degrees of axial, radial, and angular compensation capabilities, as well as different degrees of shock - absorption and buffering functions. Safety couplings transmit motion and torque and provide overload safety protection. Although the coupling is small, it is of great significance to a generator set. Therefore, we also need to pay attention to it and understand it better so that we can handle fault problems calmly.

 

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us