The function of the diesel unit pump is to generate the injection pressure for the injector. For engines using a single-pump electronic fuel injection system, there are multiple unit pumps corresponding to the number of cylinders. According to the different high-pressure generating devices, fuel injection systems can be divided into distributor pumps, in-line pumps, fuel injectors, and single-pump electronic fuel injection systems. The unit pump fuel supply system is an advanced technology for diesel engines, which can not only improve the power and economic indicators of diesel engines but also meet higher emission standards.


diesel generator maintenance


Machines, like humans, can often "get sick". If a machine is not installed and used correctly or not properly maintained, some parts may be damaged, leading to the entire machine not operating normally. Therefore, Dingbo Diesel Generator Manufacturer introduces to you today how to correctly replace the diesel unit pump and related maintenance skills.

 

Maintenance Tips for Diesel Unit Pump

1.Composition of the unit pump fuel system: Fuel comes out of the fuel tank 1, enters the diesel pump 3, then passes through the diesel filter 5 for filtration, and enters the low-pressure fuel chamber cast in the box.

2.Maintenance of the low-pressure oil circuit: It is necessary to regularly check whether the low-pressure oil circuit pressure, fuel transfer pump flow, oil return check valve and other related components are normal. In addition, the diesel engine governor also needs to be repaired and maintained regularly.

 

Precautions for Unit Pump Replacement

1.When replacing the unit pump, it cannot be simply replaced with a new one; the thickness of the unit pump gasket needs to be calculated for replacement.

2.Unit pumps of the same diesel engine cannot be used interchangeably. When it is necessary to disassemble the unit pump for inspection, special marks must be made to ensure that the unit pump and gasket of each cylinder correspond one-to-one. The unit pump cannot be assembled randomly during assembly, which is very important for the proper maintenance of the diesel generator set.

 

Guangxi Dingbo Generator Set Manufacturing Co.,Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us