Home Products News Contact Us
Home > Supports > Generator Sets > Five Tips For Diesel Generator Radiator

Five Tips For Diesel Generator Radiator

Feb. 15, 2023

The radiator of diesel generator is one of the indispensable components of generator equipment. The heat generated by the diesel generator when running under load enters the atmosphere to reduce the temperature of cooling water. The radiator must have sufficient heat dissipation area and be made of materials with good thermal conductivity. Here are five tips for diesel generator radiator:

 

1、 Drain the radiator regularly.

Radiators are very important for diesel generators and are used to help them dissipate heat. In many cases, they may cause corrosion to the radiator and affect its normal use. Corrosion can be said to be the main cause of radiator failure, because in the process of use, the air in the water will accelerate the corrosion process. Therefore, we should always keep the pipe joint from leaking, and regularly add water to discharge air from the top of the radiator to keep the system "airless".

 

2、 Precautions for radiator operation.

The coolant of diesel generator radiator is usually very hot and pressurized. Do not tidy the radiator or remove the pipe when it is not cooled. Do not work on the radiator or open the fan protective cover when the fan is running.

 

diesel generator


3、 Prevent radiator corrosion.

The radiator should not be partially filled with water, because it will accelerate corrosion. For the generator set that is not working, all water should be pumped out or filled up. If possible, use distilled water or natural soft water, and add an appropriate amount of anti-rust agent.

 

4、 Remove the deposits in the radiator.

If stubborn deposits cannot be removed in the above way, the radiator can be removed and immersed in hot alkaline water for about 20 minutes, and then washed with hot water. If the hard water irrigation method is used for a period of time due to water leakage of the joint, or the diesel generator has been running for a period of time without using rust remover, the cooling system may be blocked by scale.

 

5、 Keep the radiator outside clean.

External cleaning: In a dusty or dirty environment, the radiator joint may be blocked by debris, insects and other objects, which will affect the efficiency of the radiator. For regular cleaning of these light deposits, low-pressure hot water and detergent can be used to spray and wash, and steam or water can be sprayed from the front of the radiator to the fan. If sprayed from the opposite direction, the dirt will only approach the center. When using this method, cover the diesel engine and alternator with cloth.

 

Founded in 1974, Jiangsu Starlight Electricity Equipments Co.,Ltd., a wholly-owned subsidiary of Jiangsu Starlight Power Group, is one of the earliest manufacturers of generating sets in China. Over the past 40 years, the company has won the recognition of users by relying on advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, strong R&D technology strength. For more details, please contact us with [email protected].


Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us