When you find that the oil of the diesel generator contains water or the coolant in the radiator contains oil flakes and bubbles, we should check whether the cylinder head gasket combination of the diesel generator engine has air leakage or oil leakage. Also, during the operation of the diesel generator, you find that the diesel generator suddenly has an abnormal noise, which is very different from that in normal times, And there is clearly no power left. If any, it is a fault situation caused by damage to the cylinder gasket. The causes of cylinder gasket damage of diesel generator are briefly analyzed by Dingbo power generation equipment, including the following cases:


generator parts


1. During the maintenance of diesel generator, the cylinder gasket assembly is not smooth or the assembly direction is wrong, so the engine cylinder gasket is damaged;


2. The cylinder head of the diesel generator engine was not assembled according to the specified sequence and torque when it was installed, so the cylinder gasket was not sealed. Or the sealing is not tight;


3. The quality of the cylinder gasket is too poor, and the sealing is not tight, resulting in damage;


4. The manufacturer's master failed to properly clean the surface of the cylinder gasket during installation during maintenance, and there was dirt mixed between it and the cylinder head and cylinder block, causing damage to the gasket due to poor sealing;


5. Abnormal overheating or detonation often occurs during the operation of diesel generator, which leads to the erosion damage of cylinder gasket.


Guangxi Dingbo Generator Set Manufacturing Co.,Ltd has been established for many years. In addition to strict requirements on the quality of diesel generator set products and after-sales service, it also has strict regulations on the plant environment, production equipment and supporting facilities, which reflects the strict style of Dingbo people. It is not only responsible for generator products, customers, but also employees, so that every employee of Dingbo Power generation equipment can work in a comfortable environment, Make it comfortable for every visiting customer to visit. Dingbo Power Group, relying on high-quality generators, generator sets, diesel generator, diesel generator sets, good services and the care of friends from all walks of life, carries forward the enterprise spirit of "pragmatic innovation, pioneering, unity and hard work, dare to be the first", and adheres to the enterprise style of "treating people with sincerity and heart to heart", has won the strong support of customers in the fields of post and telecommunications, finance, petrochemical, metallurgy, transportation, education, medical care, etc, Having a proud performance. Dingbo people are gradually moving towards economies of scale and entering the international market after joining the WTO with flexible sales strategies and relying on the company's advantages and strength. If you would like to get more information welcome to contact us via [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us