We are very familiar with diesel generator sets. In various production and living occasions, we use diesel generator sets to generate electricity, which provides great convenience for users. At present, diesel generator sets can be classified in the market, which can be roughly divided into two categories: closed cooling cycle diesel generator sets and open cooling cycle diesel generator sets. They have different characteristics, so there are still some differences in the use process.


Perkins 1000KW Power generator set


The closed cooling cycle diesel generator set is mainly composed of diesel engine, AC synchronous generator, control panel and supporting devices composed of public chassis, radiator, cooling fan, etc.


The structure of the open cooling cycle diesel generator set is basically the same as that of the above closed units. The main difference is that the open unit does not have a radiator and cooling fan device, so the unit itself cannot independently complete the cooling cycle process. Users must set a cooling water radiator when using it to meet the cooling water required by the diesel engine. The open cooling cycle is generally used for high-power diesel generator sets.


The closed cooling cycle diesel generator set is fixed on the same common chassis by the diesel generator set and the generator. The power output end of the diesel generator set is directly connected with the rotor pump of the diesel generator set through the elastic sleeve pin coupling, and the diesel generator set drives the generator to work. The radiator and cooling fan are installed at the free end of the diesel generator set. The cooling fan is connected with the free end of the crankshaft through the fan drive device, and the diesel generator set drives the fan to operate, so as to implement forced cooling with cooling water. The radiator is connected with the internal cooling system of the diesel generator set through the water inlet and outlet pipes to form an independent closed circulating cooling system to provide cooling water for the diesel generator set during operation. Users do not need to set up additional cooling water cooling devices.


The use and maintenance of diesel generator sets with different classification characteristics are different. Therefore, it is necessary to understand the characteristics of diesel generator sets with different classification and carry out corresponding maintenance according to the characteristics, which can greatly improve the use stability of diesel generator sets.


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us