During operation, component wear, increased clearances, and altered fits in diesel generator sets directly affect their original performance, significantly reducing stability, reliability, and operational efficiency. Regular maintenance and repair of diesel generator sets can effectively improve equipment operating efficiency, extend service life, reduce equipment wear to enhance productivity, and lower production costs. It is essential to regularly inspect maintenance conditions and meticulously record operation and maintenance activities.


diesel generator maintenance


Targeted Maintenance Items for Diesel Generator Sets:

1.Generator and Generator Room: Perform daily cleaning and regular sweeping to minimize corrosion from dust and water.

 

2.Air Filter: Use compressed air at a distance of approximately 20cm to blow off dust from the filter, or remove and rinse with water.

 

3.Fuel Filter: Dismantle the filter element and housing every 100 hours, clean them in diesel fuel, and drain water and sediments; replace every 250 hours.

 

4.Oil Filter and Oil: Remove and clean the oil filter in diesel fuel every 100 hours; replace the filter and oil every 250 hours.

 

5.Lubricating Oil and Grease Application: Apply oil to mechanical rotating joints and grease to starter motor gears.

 

6.Radiator Water: Replace water and add rust inhibitor every 250 hours of operation.

 

7.Cooling Water Radiator: Flush with tap water once a year to remove sediments until clean.

 

8.Main Engine Idle Maintenance: Conduct idle maintenance for 15 minutes every 30 days.

 

Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd has been established for many years. In addition to strict requirements on the quality of diesel generator set products and after-sales service, it also has strict regulations on the plant environment, production equipment and supporting facilities, which reflects the strict style of Dingbo people. It is not only responsible for generator products, customers, but also employees, so that every employee of Dingbo Power generation equipment can work in a comfortable environment, Make it comfortable for every visiting customer to visit. Dingbo Power Group, relying on high-quality generators, generator sets, diesel generator, diesel generator sets, good services and the care of friends from all walks of life, carries forward the enterprise spirit of "pragmatic innovation, pioneering, unity and hard work, dare to be the first", and adheres to the enterprise style of "treating people with sincerity and heart to heart", has won the strong support of customers in the fields of post and telecommunications, finance, petrochemical, metallurgy, transportation, education, medical care, etc, Having a proud performance. Dingbo people are gradually moving towards economies of scale and entering the international market after joining the WTO with flexible sales strategies and relying on the company's advantages and strength. If you would like to get more information welcome to contact us via [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us