Home Products News Contact Us
Home > Supports > Generator Sets > Deutz Generator Working Principle and Standard Configuration

Deutz Generator Working Principle and Standard Configuration

Aug. 06, 2025

People have adapted to the lifestyle and work mode driven by electricity. Insufficient power or power outages can be really frustrating, so generators, as emergency power supply equipment, are in great demand in today's society. Deutz generator sets are one of the popular brands. Do you know the working principle and standard configuration of this equipment?


emergency power generator


Working Principle of Deutz Generator Sets

A diesel generator is a mechanical device that converts the chemical energy of diesel into mechanical energy and then into electrical energy. Its power generation principle is that other auxiliary power drives the crankshaft of the diesel generator to rotate, making the piston move up and down at the top of the closed cylinder. When the piston moves from top to bottom, the intake valve of the cylinder opens, and outdoor air is filtered by the air filter device and enters the cylinder, completing the intake stroke.

 

When the piston moves from bottom to top, the intake and exhaust valves of the cylinder are closed. Under the compression of the upward piston, the gas volume is rapidly compressed, causing the temperature in the cylinder to rise rapidly, completing the compression stroke. When the piston reaches the top, the fuel filtered by the oil filter device is atomized and injected through the high-pressure fuel injector, mixing with the high-temperature and high-pressure air for violent combustion. At this time, the gas volume expands rapidly, pushing the piston to do work downward.

 

Each cylinder works in a certain order. The thrust acting on the piston is converted into the force driving the crankshaft to rotate through the connecting rod, thereby driving the crankshaft to rotate and completing the power stroke. After the power stroke, the piston moves from bottom to top, and the exhaust valve of the cylinder opens to exhaust, completing the exhaust stroke. Each stroke rotates the crankshaft half a circle. After several working cycles, the diesel unit gradually accelerates and rotates under the inertia of the flywheel.

 

Standard Configuration of Deutz Generator Sets

1.Direct injection internal combustion engine (diesel); Deutz Engine Co., Ltd. (global warranty);

2.Pure copper brushless AC synchronous generator (single bearing, global warranty);

3.Radiator water tank suitable for 40℃-50℃ environment, belt-driven cooling fan, fan safety shield;

4.Power output air switch, standard control panel; (digital control module supports eight languages worldwide);

5.Steel common base for the unit (including: unit composite vibration-damping rubber pads);

6.Dry air filter, fuel filter, lubricating oil filter, starter motor, and self-charging generator;

7.Starting battery and battery starting connection cable;

8.Industrial 90dB muffler and standard parts for connection;

9.Molded case circuit breaker;

10.Thickened plastic film packaging;

11.Random materials: original technical documents of diesel engine and generator, generator set manual, test report, etc.

 

Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us