The cylinder block of Yuchai diesel generator set is cast, and the generator set will produce a certain vibration when it is working. Therefore, as the use time of Yuchai diesel generator set increases, the cylinder block will have a certain degree of cracks. If these cracks are not dealt with in time, it will affect the operation of diesel generator sets. Jiangsu Starlight Electricity Equipments Co.,Ltd. will introduce to you the correct repair methods for cracks in Yuchai diesel generator sets.

 

Generator repair:

1. It is bonded with epoxy resin. This process is convenient and simple to operate. The disadvantage is that it is not resistant to high temperatures and will fall off after a long time.

 

2. If the diesel generator set is not stressed, the strength requirement is small, and the crack range is short, it can be repaired with screws. This method has better results, but it is more time-consuming.

 

3. Use a plugging agent for plugging. Commonly used plugging agents include water glass and inorganic coagulant.

 

diesel generator


4. Welding repair. According to the size of the crack, the corresponding welding process can be used for remedy.

 

5. The position where the force is not strong can be sealed with a patch plate.

 

Jiangsu Starlight Electricity Equipments Co.,Ltd. reminds all users that when the Yuchai diesel generator set has cracks, you can refer to the above methods to repair the cracks of the diesel generator set. In daily use, pay attention to the daily maintenance of the unit. Once a crack is found, it needs to be dealt with in time. If the crack is relatively large, it is not recommended that the user repair it by himself, and you can contact a professional diesel generator manufacturer for treatment in time.

 

Jiangsu Starlight Electricity Equipments Co.,Ltd. is one of the earliest manufacturers of generating sets in China. It has first-class testing equipment, advanced production technology, professional manufacturing technology, perfect quality management system, and strong R&D technical strength. It can provide 3KW-2500KW various specifications of universal, automatic, four protection, automatic switching, low noise and mobile, etc., high-quality, low-energy generating sets to meet all customers' power needs, and can also meet users' different voltages and different Frequency requirements, as well as the parallel-connected power supply system of multiple units, use excellent talents to build excellent enterprises, create excellent products, create excellent services, and strive to build excellent domestic enterprises. For more product details, please contact us with [email protected]


Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us