Home Products News Contact Us
Home > Supports > Generator Sets > Causes of Difficulty in Maintenance of Cummins Generator

Causes of Difficulty in Maintenance of Cummins Generator

Jul. 25, 2023

Due to the relatively rough operation of Cummins generator, high noise, slight burning of cylinder gasket, which is difficult to detect and judge, the cylinder gasket was not replaced in time or repeatedly burned, resulting in deformation of cylinder liner of Cummins generator, damage of sealing water blocking ring, and impact of high-temperature and high-pressure gas on lintel between cylinder head and cylinder block, resulting in serious erosion grooves of Cummins generator. As a result, the maintenance of Cummins generators is difficult and the scrapping of parts is common.


generator cummins


Especially for imported engines with high compression ratio and high turbocharging, it is more prominent, seriously affecting the economic and reliability of construction machinery. The difference between the upper plane of the cylinder liner of Cummins generator and the upper plane of the cylinder block, as well as the height difference between the cylinder liners under the same cylinder head must meet the specified requirements. If it is not suitable, it should be adjusted with shims between the shoulder of the cylinder liner of Cummins generator and the cylinder block seat. During the press fitting of cylinder liner of Cummins generator, special tools shall be used for press fitting, and the force shall be uniform. It is strictly prohibited to hit and knock on the surface of cylinder liner of Cummins generator to prevent local deformation of cylinder opening of Cummins generator.


The cylinder gasket quality and the correct assembly method will directly affect its service reliability and life. So the selected cylinder gasket must be of the same specification and thickness as the original cylinder, with a flat surface, firm edge bonding, and no scratches, dents, wrinkles, or rust. Since the crimping side of the cylinder gasket of the Cummins generator has a projection, the plane connecting with it will cause indentation deformation of the Cummins generator. Generally, when the cylinder head and cylinder block of Cummins generator are made of cast iron, the crimping faces the cylinder head. If the cylinder head is made of aluminum alloy and the cylinder block is made of cast iron, the rolled edges should face the cylinder block.


Guangxi Dingbo Generator Set Manufacturing Co.,Ltd. was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo Power has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us