Home Products News Contact Us
Home > Supports > Diesel Generators > Wuxi Power Diesel Generator Models and Purchase Guide

Wuxi Power Diesel Generator Models and Purchase Guide

Oct. 29, 2025

Wuxi Power diesel generator models include the WD inline 6-cylinder series, V-type 12-cylinder series, and the Landy high-power series. As a well-known brand of domestic diesel generator sets, it is widely used in medical, agricultural, industrial, communication and other fields, and is the preferred choice for backup power in various industries. Today, the editor from Dingbo Power Generator Manufacturer will introduce the advantages and characteristics of each series for you.


generator supply


Wuxi Power WD Series 6-Cylinder Diesel Generator Set

This model uses Wuxi Power 6-cylinder diesel engine, and adopts a cylinder head intake port with large flow capacity combined with a piston straight-port combustion chamber, so that the diesel engine has a wider power range and excellent comprehensive performance. A plate-fin oil cooler is used to improve the performance and appearance of the entire diesel engine. In terms of assembly and configuration, Wuxi Power WD series selects well-known domestic and foreign brand generators such as Stamford and Engga, and controllers from reputable brands such as Deep Sea (UK) or Zhongzhi, making the entire unit more stable in performance and strong in durability.

 

WD Series 12-Cylinder Diesel Generator Set

This model uses Wuxi Power 12-cylinder diesel engine, matched with a large-flow turbocharger, high fuel supply speed PW type high-pressure oil pump, and multi-hole low-inertia fuel injector, so that the diesel engine has a wide power range and excellent comprehensive performance. Through professional transformation of the crankshaft, engine block, lubrication system, cooling system and other parts, the overall reliability of the unit is stronger.

 

Wuxi Power "Landy High-Power Series"

This series adopts Wuxi Power "Landy Series" high-power engine, which is jointly developed by Wuxi Power Engineering Co., Ltd. and AVL Company. On the basis of the original Landy series products, the overall performance of the unit is more superior, the power is stronger, and the operation is more reliable by expanding the cylinder diameter, strengthening the structure and moving parts.

 

In general, Wuxi Power diesel generator sets have the characteristics of wide power range, economical operation, reasonable and compact appearance, strong adaptability, etc., and are the best choice for users to purchase as standby power supply. Then how to correctly purchase diesel generator sets, Dingbo Power Generator Manufacturer reminds you to pay attention to the following points:

 

1.Choose a professional and reliable OEM supporting manufacturer;

 

2.Clearly understand the procurement needs: unit power, standby power and rated load power, related supporting projects, etc. Such as whether to be equipped with an automatic switching system, whether the machine room needs supporting environmental protection construction treatment. For these requirements, the professional Dingbo Power Generator Manufacturer can provide you with free design and construction plans.

 

3.Understand different price standards: diesel generator sets with the same power have different prices with different configurations, and you can choose the unit with appropriate configuration according to your own budget.

 

4.Original engineering design drawings: Regarding the floor plan of the machine room, generally professional Dingbo Power Generator set suppliers will design and layout according to your power, transmission requirements, and the size of the machine room. Users only need to easily purchase a suitable diesel generator set.

 

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us