With the development of the times and the advancement of technology, diesel generator sets are becoming increasingly intelligent and easy to operate. The addition of four major protection modules to the diesel generator set is a manifestation of this. Today, Guangxi generator manufacturer Dingbo Electric will summarize the following four protection characteristics of diesel generator sets:


generating sets


1. Diesel generator overcurrent protection. When the user's load exceeds the rated current of the generator set, a shutdown alarm occurs;

 

2. Protection for diesel generators when the water temperature is high. When the temperature of the water tank in the generator set reaches a certain level or above, a high temperature warning will be issued and the machine will be shut down for protection;

 

3. Protection for low oil pressure of diesel generator. When the engine oil in the generator is insufficient or reaches the warning level, a low oil pressure alarm will be issued and the machine will be shut down;

 

4. Diesel generator overload protection. When the user's load exceeds the rated power of the generator set, an overload alarm will be issued and the machine will be shut down.

 

A diesel generator set equipped with four protections will not encounter problems such as cylinder pulling and shaft holding that are commonly seen in ordinary diesel generator sets during operation. Because in severe cases of cylinder pulling and shaft gripping, the diesel engine of the diesel generator set may be partially scrapped.

 

The diesel generator set of Guangxi Dingbo Power has four protection and multiple protection functions, which can digitally display various data of the unit, such as line voltage, line current, output power, power factor, undervoltage, overcurrent, etc. Oil engine section: displays oil pressure, water temperature, oil temperature, speed, etc. It can be combined with multiple cabinets, and the automated intelligent control system has two modes: automatic and manual. With the grid connected system, it can jointly supply power to the load with the city grid, and remote service function can also be added. The four protection generator set is also favored by many customers due to its high degree of automation and simple operation control.

 

Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us