Home Products News Contact Us
Home > Supports > Diesel Generators > Starlight Power Teaches You To Configure Weichai Diesel Generator Set

Starlight Power Teaches You To Configure Weichai Diesel Generator Set

Jan. 29, 2023

Technical description of Weichai diesel generator set.

1. Weichai diesel generator set operating standard environmental conditions.

The atmospheric pressure is 100kPa. The ambient temperature is 25 ℃. Relative humidity 30%. Under the above conditions, when the fuel quality meets the technical requirements, the generator set can reach the rated load output.

 

2. Standards and specifications for product design.

Including but not limited to the following standards and specifications: ISO9001, GB/T 2820-2009, JB/T 10303-2001, GB/T 15548-2008, GB/T 20136-2006, etc.

 

3. When Weichai diesel generator set is in standby.

When Weichai diesel generator set is in standby for a long time, it can be manually started regularly and run at no load to check its starting performance.

 

Weichai diesel generator set


4. Fuel is applicable.

No. 0 light diesel fuel shall be selected in summer, and No. 10, - 20 or - 35 light diesel fuel shall be selected in winter according to regional climate conditions.

 

5. Lubricating oil system.

The lubricating system of Weichai diesel generator set is a closed self-circulating lubricating system. The engine is equipped with organic oil tank (oil pan), oil transfer pump, manual/electric pre-supply pump, oil filter, oil cooler, etc.

 

6. Cooling system.

The cooling water shall be slightly alkaline clean water and shall not contain corrosive compounds. Its main indicators are as follows: hardness 0.7~5.3mol/L, chloride ion content < 150mg/L, PH value 6~8.5. Use antifreeze in winter.

 

7. Start the system.

Weichai generator set is started by DC motor, and the working power supply is DC 24V. The battery is equipped with an automatic charging device, which can automatically charge it to ensure that the battery has sufficient power.

 

Weichai generator set has strong power, stable and reliable operation, simple operation, convenient maintenance, low operation cost, and is a national chain of three guarantees for units and accessories. Weichai series generator sets are widely used in hospitals, office buildings, shopping malls, factories and enterprises, residential buildings, mine outdoor engineering and other occasions as emergency standby generators, fire protection and security power supplies, and common generator sets. It is recommended to select mobile trailer type power stations (box trailers) for outdoor mining process.

 

Jiangsu Starlight Electricity Equipments Co.,Ltd. is a diesel generator set factory integrating product development, production, sales and installation. The company has successfully developed a series of diesel generator sets with high-tech technology, and has formed industrial production. The main products are: silent series, mobile trailer series, container series diesel generator sets. For more details, please contact us with [email protected].


Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us