Fan belt plays a vital role in the operation of diesel generator set. Keeping the fan belt of Shangchai diesel generator set in normal tightness is an important prerequisite to ensure the normal operation of the cooling system of Shangchai diesel generator set. The generator manufacturer introduces several reasons for the fan belt fracture of Shangchai diesel generator set.

 

1. First of all, consider the fan belt quality and model factor system. Only genuine and original quality belts are not likely to break. Fake and inferior belts or substitutes have poor quality and are very easy to wear, increasing the risk of fan belt breakage.

 

2. Whether the installation method of the fan belt is correct, and the incorrect installation method is also the cause of the belt fracture. The side of the belt should be on the same plane, and the belt should not be too tight or loose after installation. Under normal conditions, when the fan belt is pressed down at the middle of the fan wheel and the generator wheel with a force of 3-5 KG, it is appropriate that the fan belt drops 10-20 mm from the balance position.

 

Shangchai diesel generator set


3. If the fan belt is not used for a long time, it will also be weathered or the belt pulley will be rusted. It is also easy to use the belt to break during operation.

 

4. Another is the main reason for the fan belt fracture: the main reason is that the pulleys of the same group do not work on the same plane, which causes the belt to be severely worn in a short time. Jiangsu Xingguang Company suggested that if there are many black belt scraps near the fan belt of the engine, the pulley does not work on the same plane. In addition, when the fan belt is working, carefully observe the radial or axial runout of the belt pulley to find problems in time and eliminate faults.

 

Jiangsu Starlight Electricity Equipments Co.,Ltd. reminds users that the fan belt must be regularly maintained and inspected every day. If the fan belt of Shangchai diesel generator set is found sticky or hard, it indicates that the fan belt is aging and should be replaced in a timely manner.

 

Jiangsu Starlight Electricity Equipments Co.,Ltd. is a professional manufacturer of generators, diesel generator sets, Shangchai generator sets, Volvo generator sets, etc. It has 64 sales and service departments, and provides users with one-stop service of design, supply, debugging and maintenance at any time. Welcome the majority of users call for consultation. For more details, please contact us with [email protected].


Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us