How to regularly check the wear of the keyways and fixing bolts related to diesel generator sets, using standard high-pressure oil pipes. During the fuel supply process of the fuel injection pump, due to the compressibility of diesel and the elasticity of the high-pressure fuel pipe, high-pressure diesel will form pressure fluctuations inside the pipe. The transmission of pressure waves inside the pipe requires a certain amount of time. To ensure consistent fuel supply interval angle, uniform fuel supply, and stable operation of the diesel generator set, the length and diameter of the high-pressure fuel pipe are selected through calculation.


diesel genset


Therefore, when the high-pressure oil pipe of a certain cylinder is damaged, a standard length and pipe diameter oil pipe should be replaced. In practical use, due to the lack of standard oil pipes and the use of other oil pipes instead, regardless of whether the length and diameter of the oil pipes are the same, there is a significant difference in the length and diameter of the oil pipes. Although it can be used for emergency purposes, it will cause changes in the fuel supply advance angle and quantity of the cylinder, resulting in unstable operation of the diesel generator set. Therefore, it is necessary to use standard high-pressure oil pipes in use.


And it is necessary to regularly check the wear of the relevant keyways and fixing bolts of the diesel generator set. The relevant keyways and bolts mainly refer to the camshaft keyways, coupling flange keyways (oil pumps that transmit power through couplings), half round keys, and coupling fixing bolts. The camshaft keyway, flange keyway, and semicircular key of the fuel injection pump may wear out due to long-term use, causing the keyway to become wider, the semicircular key to not be firmly installed, and the fuel supply advance angle to change; The heavy key falls off, causing power transmission failure. Therefore, it is necessary to regularly inspect, repair or replace worn components in a timely manner.


Guangxi Dingbo Generator Set Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us