Users who often pay attention to the technical trends of diesel generator sets may know that adding carbon removal rings to the piston heads of diesel engines of diesel generator sets can reduce oil consumption. How is this function applied? What is the functional principle of the carbon removal ring of the diesel generator set? In this article, Starlight Dynamics summarized the following contents to share with you.


generator maintenance


After the carbon removal ring is installed in the diesel generator set, the cylinder liner has formed a typical stepped shape, which reflects a series of advantages of the stepped cylinder liner. It plays an important role in reducing the oil pollution, reducing the number of back flushing of the filter, extending the life of the automatic filter element, and extending the service time of the oil. It is beneficial to the maintenance and even the extension of the service life of the entire auxiliary system.


The specific principle is as follows: at the moment of combustion explosion stroke, as the carbon deposit on the piston head is scraped off, when the fuel gas flows downward, it is blocked from turning around the cutting edge of the carbon removal ring, and the pressure drops rapidly. The piston ring bears low pressure. The sealing property is enhanced, and the fuel gas will not flow into the cylinder liner and crankcase to pollute the engine oil, which extends the service time of the engine oil and reduces a lot of oil change losses.


At the same time, there is a good clearance between the piston ring and the ring groove, which reduces the oil pumping phenomenon of the reciprocating movement of the piston. Even if the oil pumped is blocked at the edge of the carbon removal ring, part of the oil is blocked, the speed of the oil pressure that goes up has been reduced, the oil that goes into the combustion chamber is greatly reduced, and the oil that is burned is also reduced. In this way, a large amount of oil is saved, which is why the carbon removal ring is added to reduce the oil consumption.


Through the above explanation, you should understand how the carbon removal ring plays a role in the diesel generator set. If you want to control the oil consumption, you can try this method.


Starlight Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us