Do you know the precautions for load inspection of diesel generator sets? Today, we will answer the precautions regarding how to carry out load inspection on diesel generator sets. Firstly, how to carry out load inspection on diesel generator sets is usually tested in the factory. The following precautions are introduced. Firstly, N sets of load devices should be selected based on the maximum load power of the diesel generator set, and cables should be used to connect the diesel generator set, control output cabinet, and load device.


cheap diesel generator


Secondly, the diesel generator set should be started first and gradually loaded to 25%, 50%, 75%, and 100% of the full load. Based on the data displayed on the control screen, various data such as water temperature, voltage, and current should be recorded for each stage (usually with a diesel generator set load test table) to see if the diesel generator set operates normally, whether the output current is stable, and whether the segmented capabilities of the control output cabinet are available, The specific testing time can be determined based on the actual working time required by the diesel generator set.


If strict testing is required, a third party (such as a technical testing station) needs to be entrusted for testing and relevant test reports should be issued.


Guangxi Dingbo Generator Set Manufacturing Co.,Ltd has been established for many years. In addition to strict requirements on the quality of diesel generator set products and after-sales service, it also has strict regulations on the plant environment, production equipment and supporting facilities, which reflects the strict style of Dingbo people. It is not only responsible for generator products, customers, but also employees, so that every employee of Dingbo Power generation equipment can work in a comfortable environment, Make it comfortable for every visiting customer to visit. Dingbo Power Group, relying on high-quality generators, generator sets, diesel generator, diesel generator sets, good services and the care of friends from all walks of life, carries forward the enterprise spirit of "pragmatic innovation, pioneering, unity and hard work, dare to be the first", and adheres to the enterprise style of "treating people with sincerity and heart to heart", has won the strong support of customers in the fields of post and telecommunications, finance, petrochemical, metallurgy, transportation, education, medical care, etc, Having a proud performance. Dingbo people are gradually moving towards economies of scale and entering the international market after joining the WTO with flexible sales strategies and relying on the company's advantages and strength. If you would like to get more information welcome to contact us via [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us