Perkins series, unit power 16-1800KW. Perkins is one of the world's three diesel engine manufacturers. Perkins is widely used in industry, engineering machinery, agriculture, marine, and power generation equipment for its high performance, quality and reliability.

 

1. Electrical performance of Perkins generator set:

Comply with GB2820 and ISO8528/3 standards, and meet the technical requirements of YD/T502 special diesel generator set for communication of post and telecommunications system.

Rated voltage: 400/230V.

Wiring mode: 3-phase 4-wire.

Frequency: 50Hz.

Rated power factor: 0.8 (lagging).

Radio interference suppression: comply with VDE0875-N and GB2820.

 

2. Perkins generator set standard:

Comply with GB/T2819, ISO8528, IEC34, etc.

The rated output power of the generator unit shall comply with.

The altitude shall not exceed 1000m.

The ambient temperature is 0 ℃~40 ℃.

The relative humidity of the air is 60%.

 

Perkins generator set


3. Perkins Generator Set Alternator:

Excitation mode: brushless self excitation.

Insulation class: Class H.

Protection grade: IP21~IP23.

Voltage regulation: automatic regulation.

 

4. Perkins generator set control box:

There are different types of control boxes, such as manual, automatic, remote monitoring, automatic and intelligent. The basic configuration includes voltmeter, ammeter, water temperature meter, oil pressure meter, controller, emergency stop button, preheating button, battery voltmeter, timetable, phase selection switch, etc.

 

5. Perkins generator set principle:

In the cylinder of the diesel engine, the clean air filtered by the air filter is fully mixed with the high-pressure atomized diesel fuel injected from the fuel injection nozzle. Under the upward extrusion of the piston, the volume shrinks and the temperature rises rapidly, reaching the ignition point of the diesel fuel.

The diesel fuel is ignited, the mixed gas burns violently, the volume expands rapidly, and pushes the piston downward, which is called "work". Each cylinder works in a certain order. The thrust acting on the piston becomes the force that drives the crankshaft to rotate through the connecting rod, thus driving the crankshaft to rotate. When the brushless synchronous alternator is installed coaxially with the crankshaft of the diesel engine, the rotation of the diesel engine can be used to drive the rotor of the generator. Using the electromagnetic induction principle, the generator will output the induced electromotive force, and the current can be generated through the closed load circuit.

 

Jiangsu Starlight Electricity Equipments Co.,Ltd. has a young and professional technical backbone team, with an average working age of more than 10 years in the generator unit industry. There are 64 sales and service departments throughout the country to provide users with a one-stop service of machine room design, equipment supply, commissioning and maintenance at any time. No matter when and where, a well-trained service team will provide you with comprehensive and considerate protection. For more details, please contact us with [email protected].


Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us