Home Products News Contact Us
Home > Supports > Diesel Generators > Improve The Environmental Pollution of Diesel Generator Set

Improve The Environmental Pollution of Diesel Generator Set

Mar. 13, 2023

The problem of fuel oil pollution of diesel generator sets has been an important subject for many experts to study deeply, and its significance is to improve the safety and environmental protection of the operation of generator sets. Among many studies, it is proposed that mixing fuel with water can improve the pollution of diesel generator sets, which has been proved to be a good method. Starlight will introduce two methods of mixing fuel with water.


genset price


The methods of mixing fuel with water include intake pipe spray and emulsified diesel oil.


1. Intake pipe spray


The main function of the intake pipe spray is to absorb heat and dilute the fuel density. When a small amount of water enters the combustion chamber and atomizes well, due to the "micro explosion" effect of water vapor, the oil droplets break into smaller oil droplets, thus promoting the formation and combustion of the mixture. During the combustion process, the maximum combustion temperature can be reduced due to the heat absorption of water. For example, the mixture of water and oil can reduce the fuel density, further reduce the maximum combustion temperature, and thus reduce NOx emissions. It should be noted that the storage tank of diesel generator set in winter should be antifreeze, and the water spray volume should be automatically adjusted according to the load.


2. Emulsified diesel


Mixing water in diesel, that is, emulsified diesel, because of its "micro explosion" effect, makes its fuel atomization good, and promotes the air in the combustion chamber to form strong turbulence, the distribution of fuel and air is more uniform, and the generated soot is reduced. The water gas reaction of water vapor also reduces the soot emission. In addition, emulsified diesel can reduce the maximum combustion temperature, thus reducing the amount of NOx generated.


The above two methods are to promote the combustion of fuel by adjusting the fuel oil. After the combustion is sufficient, the harmful gas emitted by the diesel generator set will naturally decrease, which is quite effective in reducing environmental pollution and ensuring the safety of the working environment. It is an environmental protection measure that kills two birds with one stone and should be popularized.


Jiangsu Starlight Power Generation Equipment Co., Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Starlight has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us