Handling of Silent Generator Set After Idle

Jul. 05, 2023

If a quiet generator set is idle for a long period of time and then restarted, there will be no AC voltage output phenomenon. In order to prevent short circuits at the output end of the silent generator set from causing excitation to be unable to be established, the main output circuit of the silent generator set is checked. If there is an excitation and magnetization button, press the excitation and magnetization button. If there is no excitation button, use a battery to magnetize it.


super quiet generator


If the silent genset is not used for a long time, the residual magnetism contained in the iron core before leaving the factory will be lost, and the excitation coil will not establish the necessary magnetic field. At this time, the silent generator set will operate normally but cannot generate electricity. Therefore, everyone should pay more attention when using it. The silent generator set can operate as a single unit, or as multiple units in parallel or integrated into the power system. If its power meets the requirements of heavy-duty operating conditions, the economy of silent generator set operation will be reduced during light load operation.


And its backup silent generator set also needs to have the same capacity as the operating silent generator set. By using multiple silent generator sets to operate in parallel and integrate into the power grid, the power supply capacity can be expanded and the reliability of the power supply can be improved. One backup silent generator set is sufficient, which relatively reduces the capacity of the backup silent generator set. The terminal voltage is equal, the frequency is equal, the phase is consistent, and the phase sequence is consistent. At the same time, there should also be an operational protection device that can automatically and reasonably allocate and adjust active and reactive power, so that the frequency regulation characteristics and voltage regulation characteristics curves between silent generator sets tend to be close.


Since 1982, Starlight Generator has been a generator set manufacturer qualified by the "National Internal Combustion Engine Quality Supervision and Inspection Center". The product quality has passed the IS09001 quality system standard certification. And obtained the qualification certificate for self-operated import and export. Over the years, starlight units have been widely used in all walks of life, and have won the network access qualification of the Ministry of Information Industry, the network access qualification of the Ministry of Radio and Television, the network access qualification of CNPC, the network access qualification of China Mobile, and the manufacturing qualification of marine units. In 2016, Starlight was awarded the Certificate of Qualified Supplier of China Nuclear Power Group. Starlight Generator has been cooperating with Shangchai Power for many years. In 2009, it became the OEM partner of Shangchai Power in China. Starlight generator VOLVO unit ranks the top three in the Asia-Pacific sales volume, and is the core OEM partner of Sweden Volvo in the Asia-Pacific region. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us