After the Cummins diesel generator set is installed, the Cummins diesel generator set must be fully inspected before it is put into operation, otherwise it is prone to safety failures, which should be paid attention to. Therefore, after the Cummins diesel generator set is installed, Starlight will conduct basic debugging work on the Cummins diesel generator set to test whether the Cummins diesel generator set is in good condition and whether it is working properly.

cummins diesel genset.jpg

Fill the water tank of the Cummins diesel generator set with water, close the drain valve of the Cummins diesel generator set, add clean drinking water or pure water to the water tank port of the Cummins diesel generator set, and cover the water tank. Oil is divided into summer and winter. Different oils are used in different seasons. In the process of refueling, pay attention to the vernier scale until the oil is filled to the full position of the vernier scale. In order to ensure that the oil inlet of Cummins diesel generator set is clean, diesel is usually stored for 72 hours. Do not insert oil into the bottom of the cylinder to avoid sucking in dirty oil and blocking the oil pipe.


Loosen the nut on the hand oil pump, hold the handle of the Cummins diesel generator hand oil pump, and evenly pull and compress until the oil enters the pump. To loosen the bleed screw of the high-pressure oil pump of the Cummins diesel generator set, and then press the manual oil pump, the oil and air bubbles overflow in the screw hole until all the oil is seen flowing out, and finally tighten the screw. Connect the negative pole of the motor and make sure it is firmly connected to avoid ignition and burning of the wiring part. Before starting the Cummins diesel generator set or the Cummins diesel generator set is not in the power state, the switch should be in a separate state.


During the Cummins diesel generator sets working, the power readings used are accurate, and the voltmeter used to detect the output voltage of the Cummins diesel generator set motor must reach 50 Hz. This is the basis for measuring speed. It is used to test the oil pressure of the diesel engine of Cummins diesel generator set. At full speed, it should be no less than 0.2 atmospheres, and the tachometer should be 1500 rpm. During the use of Cummins diesel generator set, the temperature cannot exceed 95 degrees, and the oil temperature generally cannot exceed 85 degrees. Turn on the ignition switch, press the button, release the Cummins diesel generator set after landing, run for 30 seconds, toggle the high and low speed switch, the Cummins diesel generator set slowly rises to high speed at idle speed, and check the readings of the Cummins diesel generator set. Under all normal conditions, the air switch can be turned on and the power transmission is successful. When the Cummins diesel generator set stops, first turn off the air switch and cut off the power supply. The Cummins diesel generator set will be adjusted from high speed to low speed.


Jiangsu Starlight Power Generation Equipment Co., Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Starlight has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us