Check Whether The Throttle Lever of Diesel Generator Set is Flexible

May. 23, 2023

The main reasons for the lack of smoke in the exhaust pipe of the generator set are the lack of oil in the fuel tank of the generator set, the malfunction of the shutdown solenoid, and the malfunction of the fuel shut-off valve. If the fuel tank is empty, add fuel, and the shutdown solenoid is faulty. Check the shutdown solenoid of the generator set.


china diesel generator


If necessary, replace the generator set. If the fuel shut-off valve of the generator set is faulty, see "Possible faults of the fuel shut-off valve". If there is no oil spraying from the fuel injector, loosen the oil pipe between the fuel injection pump and the cylinder head of the generator set. Start the engine at the same time, check whether there is fuel overflow in the generator set, the oil transfer pump suction pipe connector is loose, tighten all the filter pipe connectors between the generator set oil tank and the oil pump, the fuel filter is blocked or the suction pipe is blocked, and replace the generator set fuel filter.


Check if the fuel hose of the generator set is blocked, if there is no fuel in the oil pump, if there is a blockage in the oil pump, or if there is a blockage in the intake or exhaust system of the generator set. Check if there is a blockage in the intake and exhaust system of the generator set, if the drive shaft of the generator set oil pump is broken, or if the gear pump is pulled or worn. The oil delivery pump of the generator set is malfunctioning, and the nozzle hole of the fuel injector is blocked. Check and repair the oil delivery pump of the generator set, and replace it if necessary.


In daily life, power failure also happens frequently. At this time, the diesel generator set is an extremely important existence, which can solve this problem very well. Sometimes the user starts the diesel generator set and will exceed the speed limit. Check the instrument connection circuit of diesel generator set, sensor, control panel or connection failure. Observe whether the connection between the diesel generator set sensor and the control panel is loose or disconnected, and check whether the diesel generator set sensor needs to be replaced.


The diesel generator set has overspeed, and the overspeed protection setting is too small. The user should slightly adjust the overspeed protection value of the diesel generator set so that it does not exceed 17%. If the diesel generator set adopts a mechanical speed regulating structure, please check whether the throttle lever of the diesel generator set is flexible and ensure that the adjustment is correct.


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Contact Us
  • Add.: Room 601, Laboratory Building, No.2 Gaohua Road, Nanning, Guangxi, China.
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Guangxi Dingbo Power Equipment Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

seokeywords:

test2
Contact Us