What is Mecc Alte SR7 AVR?


generator parts


The Mecc Alte SR7 AVR is an analog automatic voltage regulator. This was widely applied to Mecc Alte AC generators before they switched to digital AVR.

 

The main function of AVR is to maintain voltage load under steady-state and transient conditions when applied to diesel generators.

 

What happens when you apply a load to a brushless AC generator?

 

When you apply for a load on an AC generator, its response is a voltage drop at the output terminal. On the contrary, removing some loads will cause an increase in voltage at the generator terminals. The magnitude of the decrease depends on key factors such as the design of the AC generator, its components, its excitation system (such as shunting, auxiliary ports), and its automatic voltage regulation.

 

If the AC generator is connected to a diesel engine, the engine will also respond to the application of the load, which will have an impact on the overall diesel generator system.

 

When the load is applied to the AC generator, the increase in current causes a decrease in voltage on the main stator and generator terminals of the AC generator. This voltage drop is called a transient voltage drop, and then the excitation system responds by attempting to restore the voltage to a predetermined stable state.

 

The AVR senses a decrease in voltage through its connection to the AC generator terminal and increases its flow to the exciter stator, which in turn increases the generator terminal.

 

Unlike when applying for a fixed speed engine load, you usually hear the engine's response. The voltage drop in an AC generator can only be seen using measuring equipment such as a multimeter or by reading from the generator control panel.

 

In the case of a large applied load, the voltage may significantly decrease and this effect can be observed. The lighting connected to the load may flicker, and sensitive electronic devices may shut down or malfunction.

 

What protection features are built-in in the Mecc Alte SR7?

 

SR7 operates low-frequency protection. This will monitor the frequency of the output voltage and send control signals to correct the problem.

 

SR7 can also prevent overload. Overload protection will also protect the AC generator from excessive excitation.

 

Founded in 1974, Dingbo Power Generation Equipment Co., Ltd. is a professional manufacturer of diesel engines, generators and generator sets, and one of the earliest manufacturers of diesel engines, generators and generator sets in China. Since 1992, the company has been a qualified generator set manufacturer inspected by the National Internal Combustion Engine Generator Set Quality Supervision and Inspection Center. Over the years, the company has carried out extensive cooperation with Shanghai Diesel, Weichai, Sweden Volvo, Sino US joint venture Chongqing Cummins, American Qianglu and other companies, and has become a (OEM) supporting factory and technical center. It has 64 sales service departments nationwide, providing users with design, supply, commissioning and maintenance services at any time. Dingbo quality is worth depending on. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us