Technical Parameters of 620kw Weiman Diesel Generator Set DE22A840

Mar. 22, 2024

It is understood that Weiman Power's products include energy-saving and environmentally friendly high-power diesel engines with a capacity of 11-30L, covering a power range of 240kW to 1100kW. Multiple models of diesel engines have passed the emission certification of China's third and fourth stages. The product is widely used in engineering machinery, diesel generator sets, and other applications.


diesel generator 250 kw


The 620kw Weiman diesel generator set of the Dingbo series is equipped with the DE22A840 Weiman diesel engine produced by Shanghai Yangfa Power Co., Ltd. It introduces and absorbs advanced design, production, and management concepts and technologies from European and American engines, adopts a V-shaped arrangement, has the characteristics of low compression ratio and collective structural strengthening. The relevant technical parameters of the 620kw Weiman diesel generator set DE22A840 are as follows:

Genset Model

DB-620GF

Genset Output Power (KW/KVA)

555/755

Brand and Model

WeimanDE22A840

Manufacturer

Shanghai Yangfa Power Co., Ltd

Diesel Engine Power (KW) Main/Standby

620/844

Cylinder Diameter x Stroke (mm)

128×142mm

Cylinders Number

12

Oil Capacity(L)

50

Speed Control

electronic speed control

Rated Frequency

50Hz

Rated Speed

1500rpm

Output Current

900A

Output Voltage

400V/230V

Start Mode

DC24V Electric Start

Cooling Method

Closed Water Circulation Cooling

Fuel Consumptiong/kw.h

≤192

Emission

China Stage III

External Dimensions
L×W×H(mm)

1717×1389×1288

Generator Set Weight(kg)

1575


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us