Yuchai diesel generator sets are currently widely used in industrial and agricultural production, national defense, science and technology, daily life and other fields. In recent years, with the advancement of technology, lightweight and portable small generator sets have begun to enter residents' daily lives as an excellent choice for home emergency power supplies and outdoor travel power supplies. However, the quality of the generator sets directly affects national security and people's lives. Therefore, the Yuchai diesel generators we use need to meet the requirements of various performance indicators, such as power performance indicators, weight and size indicators, economic indicators, exhaust pollution indicators, etc.


Yuchai diesel generator


1.Weight and Overall Dimension Indicators

The weight and overall dimension indicators can be used to evaluate the structural compactness and metal material utilization rate of a diesel engine. Different types of diesel engines have different requirements for overall dimensions and weight.

 

(1) Weight Indicator

The weight indicator of a diesel engine is the ratio of the net weight Gw of the diesel engine to the rated power Pe, that is, gw=Gw/Pe (kg/kW). The net weight of the diesel engine does not include auxiliary equipment and systems not directly installed on the internal combustion engine body, such as fuel, lubricating oil, and cooling water. The weight of the diesel engine is affected by its type, structure, size of accessories, materials used and manufacturing technology.

 

(2) Overall Dimension Indicator

The overall dimension indicator is also called the compactness indicator, which refers to the compactness indicator of the overall layout of the diesel engine. It is usually determined by the power per unit volume of the diesel engine. The power per unit volume PV is the ratio of the rated power Pe of the diesel engine to the external volume V of the diesel engine, that is, Pv=Pe/V kW/m³. In the formula, V=LBH, where L, B and H are the maximum length, width and height dimensions of the diesel engine.

 

2.Exhaust Pollution Indicator

Diesel engine exhaust contains small amounts of harmful emissions, including carbon monoxide, hydrocarbons, nitrogen oxides and sulfur dioxide. These combustion products are emitted into the atmosphere, polluting the environment, endangering human health and causing social hazards.

 

With the enhancement of environmental awareness, the restrictions on diesel engine exhaust pollution are becoming increasingly strict. The national standards implemented in China have the following restrictions on carbon monoxide emissions from diesel engines: When Pe>300kPa, the NOx limit is 29g/kW·h when ge≤214g/kW·h; when ge=214-268g/kW·h, the NOx limit is 14-25g/kW·h; when ge>268g/kW·h, the NOx limit is 11g/kW·h.

 

Guangxi Dingbo Generator Set Manufacturing Co.,Ltd. has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3kW~2500kW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us