The closed circuit breather separator is mounted on the right hand side of the gearcase and is connected to the air inlet system between the air cleaner and turbocharger via the breather valve
Remove the filter separator canister using a strap wrench see Fig. 33 fill the new filter/ separator with clean engine oil to the rubber seal, then screw the canister onto the housing using firm hand pressure.
3 Check that the filter sealing surface is clean. 4 Install a new filter (3) and a new O-ring (2). 5 Install the filter cover (1) and filter. Tightening torque: 40 Nm (29.5 lbf. ft.) 6 Fill with engine oil; refer to Administration page 16. 7 Start the engine and check that there is oil pressure. 8 Check that no leakage is present. 9 Stop the engine and check the oil level after a couple of minutes.
Start the engine and check the oil pressure. If the oil pressure measurement shows that the pressure is below the specified minimum value, continue fault tracing by checking the oil filters. If the oil pressure measurement using an external pressure sensor shows that the pressure is within tolerances, but the regular engine pressure sensor does not, replace the regular pressure sensor.