When using diesel generator sets for a long time, the cost of fuel consumption is also a significant expense. Therefore, when purchasing a diesel generator set, in addition to comparing prices, it is necessary to carefully check the fuel consumption rate of the unit. Most importantly, during the use of the generator set, on the premise of giving full play to the working efficiency of the generator set, try to reduce diesel consumption and save fuel. Yuchai diesel generator sets, featuring high horsepower, high torque, fuel - saving, low emissions, and low noise, have become the preferred backup power sources for major commercial centers, data centers, factories, and the aquaculture engineering industry in China.


Yuchai diesel generator


The efficiency of the engine affects fuel economy. The 100kW Yuchai diesel generator is designed and manufactured with a process that brings the highest fuel efficiency for all application types. Follow the recommended steps to achieve the best performance over the engine's service life.

 

Avoid fuel spillage. Fuel expands when heated and may overflow from the fuel tank. Check the fuel lines for leaks and perform the necessary repairs.

Know the characteristics of different fuels. Only use the recommended fuel.

Avoid running under low - load conditions if not necessary. If the Yuchai engine has no load, turn it off.

Frequently check the air filter maintenance indicator. Replace the air filter element when it is dirty.

Maintain the electrical system. A faulty battery can cause the alternator to work excessively, which consumes extra power and fuel.

Ensure that the drive belt is properly adjusted and in good condition.

Ensure that all hoses are tightly connected and there are no leaks at the joints.

Ensure that the driven equipment is in good condition.

A cold engine consumes excessive fuel. Make the most of the heat from the cylinder liner water system and the exhaust system as much as possible. Keep the cooling system components clean and well - maintained. Never run an engine without a thermostat installed. All these measures will help maintain the working temperature.

 

Finally, users must pay attention to regularly inspecting and promptly repairing the 100kW Yuchai diesel generator set. Be diligent in observing and taking action. Regularly or irregularly inspect the machinery, and be diligent in maintenance and repair. Firmly establish the concept that "maintenance is more important than treatment, and prevention is more important than repair" to extend the service life of the unit and save fuel.

 

Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3kW~2500kW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us