Home Products News Contact Us
Home > Supports > Diesel Engine > Factors Affecting the Accuracy of Diesel Generator Dimensions

Factors Affecting the Accuracy of Diesel Generator Dimensions

Jul. 02, 2025

The dimensions of a diesel generator are related to a series of issues such as transportation and installation. Therefore, manufacturers must measure the assembled generator set before providing the data. Only such data can be accurate.


standby generators for sale


Sometimes, customers need to know the dimensions of the diesel generator in advance to renovate or construct the generator room. At this time, the Cummins diesel generator has not been assembled yet, so real data cannot be provided. Therefore, the data provided by the manufacturer are all measured from previously assembled units. Why is this data inaccurate? Let's analyze the reasons below:

 

1.Different diesel engines are used: Even for diesel engines of the same power range from different brands, their length, width, and height vary. Each manufacturer has different workmanship and design, so the size of the diesel engine is different.

2.Different generators are used: Generators can be divided into domestic and imported ones. The dimensions of generators manufactured by different manufacturers are definitely different, and the reason is the same as above.

3.Different brands of water - tank radiators are used: Generally, the water - tank radiator determines the overall height of the diesel generator. The height varies with different manufacturers.

4.Whether it has undergone special modifications: This is a complex situation. Some customers require the diesel generator to be used in special environments and will add enclosures, trailers, etc. to the diesel generator. These have a huge impact on the dimensions. Therefore, no one can accurately know the dimensions of the unit before it is installed.

 

In many cases, the data provided by the manufacturer are relatively accurate for unmodified generator sets, but the estimated actual dimensions of modified generator sets have a relatively large gap. For customers who are in a hurry to design the generator room, they must not rush to ask the manufacturer for approximate data. They must wait until the unit is assembled and then ask the manufacturer for accurate data.

 

Therefore, when customers inquire about the dimensions of the diesel generator, they must clearly state information such as the brands of the entire unit, the diesel engine, the generator, and the water - tank radiator, as well as whether it has been modified. The more accurate the information provided, the more accurate the obtained data will be. Otherwise, the obtained data are meaningless.

 

Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us