What is Radiator Coolant?

Radiator coolant is a liquid with functions such as anti-boiling, anti-corrosion, anti-rust, and anti-foam, which can be mixed with any antifreeze and cooling water.


generator maintenance


What is Antifreeze?

Antifreeze, full name antifreeze coolant, is mainly divided into ethylene glycol antifreeze, glycerol antifreeze and propylene glycol antifreeze. The commonly used type in China is ethylene glycol antifreeze. Antifreeze has the characteristics of high boiling point and low freezing point. It also has the functions of antifreeze in winter, anti-boiling in summer, anti-corrosion, anti-rust and anti-scale throughout the year.

 

What is the Difference Between Radiator Coolant and Antifreeze?

Radiator coolant and antifreeze have roughly the same composition and efficacy, but what exactly is the difference between them? Radiator coolant has a higher freezing point than antifreeze and is more likely to freeze. Therefore, radiator coolant is not suitable for northern regions where the outdoor temperature is generally below 0 degrees Celsius in winter.

 

How Often to Replace Diesel Generator Radiator Coolant or Antifreeze?

Generally speaking, the packaging of radiator coolant produced by regular manufacturers will indicate "suitable for areas above 0 degrees". You can carefully check when purchasing. If you plan to replace radiator coolant with antifreeze, you need to completely drain the radiator coolant and thoroughly clean the radiator first. After that, it is recommended to directly choose antifreeze, so that you can use it with confidence whether in winter or summer, whether in the north or south.

 

Under normal conditions, it should be replaced once a year, but regular inspections should be carried out at ordinary times. Generally, generators have a winter preheating function. When the temperature is low, turning on the preheating will prevent problems such as failure to start or difficulty in starting during power generation. This preheating function does not need to be turned on in summer or when the temperature is high.

 

How to Distinguish Good and Bad Diesel Generator Radiator Coolant?

Radiators are generally divided into copper radiators and aluminum radiators. You can tell by scratching the fins on the radiator.

 

Guangxi Dingbo Generator Set Manufacturing Co.,Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us