Home Products News Contact Us
Home > Supports > Diesel Engine > Check The Valve Clearance of Shangchai Diesel Generator Set

Check The Valve Clearance of Shangchai Diesel Generator Set

May. 24, 2023

If the Shangchai diesel generator is equipped with an air compressor, please replace the air filter on the air compressor by opening the valve fastening device, removing the filter of the Shangchai diesel generator set and then destroying it, installing a new filter and tightening the screws, cleaning the cooling system and replacing the coolant, which is only applicable to devices without coolant filter.


shangchai diesel generating set


It is also required that qualified engineers and technicians who have received professional training should check the valve clearance of Shangchai diesel generator set, stop the Shangchai diesel generator set during the inspection, maintain it every 2400 hours, and complete the inspection every 1200 hours. Professional technicians should check the status of the turbocharger of Shangchai diesel generator set, and conduct a comprehensive inspection of the components of Shangchai diesel generator set, Replace the coolant filter every 6 months for maintenance.


Close the cooling faucet of Shangchai diesel generator set, remove the filter of Shangchai diesel generator set with special tools, and then reinstall a new one. Finally, open the tap, clean the cooling system, and replace the coolant of the diesel generator set. It is only applicable to the diesel generator set with coolant filter, and check whether there is leakage. Low coolant level, thermostat valve failure, exhaust fan failure, or blockage of intercooler, radiator or other components of the cooling system may cause the coolant temperature of the diesel generator set of Shanghai Diesel Engine Co., Ltd. to be too high.


After the diesel generator set of Shangchai has fully operated for 50 hours, check the storage battery of the diesel generator set of Shangchai, 3 liquid leaks, 3 filtering systems, the tightness of the fan belt, the connection head of the diesel generator set of Shangchai and the increase of the electric control part. Check the battery of Shangchai diesel generator set, measure the battery voltage of Shangchai diesel generator set, add if necessary, and wear goggles when carrying the battery.


The battery contains explosive gas and corrosive sulfuric acid. The ignition near the battery may lead to the explosion of the Shangchai diesel generator set. Check whether there are three kinds of liquid leaks from the Shangchai diesel generator set, check whether the three filter system of the Shangchai diesel generating set is intact, replace it if necessary, check and adjust the tightness of the fan belt of the Shangchai diesel generator set.


Add or replace the cooling water in the water tank and vehicle body, and check whether the connectors of Shangchai diesel generator set and electronic control part are reliable. The oil-water separator shall be used, and the diesel generator set shall be regularly discharged, cleaned or replaced every 50 hours. After the new diesel generator set runs for 50 hours for the first time, replace all oil and oil filter of the diesel generator set.


Starlight Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us