OVERALL SIZE: 245 mm x 184 mm x 51 mm (9.6" x 7.2" x 2.0")

PANEL CUTOUT SIZE: 220 mm x 160 mm (8.7" x 6.3")

MAXIMUM PANEL THICKNESS: 8.0 mm (0.3")

PRODUCT VARIANTS

7320-03 - 7320 MKII Auto Mains Failure Control Module


SPECIFICATION

DC SUPPLY

CONTINUOUS VOLTAGE RATING

8 V to 35 V Continuous

5 V for up to 1 minute

CRANKING DROPOUTS

Able to survive 0 V for 100 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking.

MAXIMUM OPERATING CURRENT

510 mA at 12 V, 240 mA at 24 V

MAXIMUM STANDBY CURRENT

330 mA at 12 V, 160 mA at 24 V

CHARGE FAIL/EXCITATION RANGE

0 V to 35 V

GENERATOR & MAINS (UTILITY)

VOLTAGE RANGE

15 V to 415 V AC (Ph to N)

25 V to 719 V AC (Ph to Ph)

FREQUENCY RANGE

3.5 Hz to 75 Hz

MAGNETIC PICK UP

VOLTAGE RANGE

+/- 0.5 V to 70 V

FREQUENCY RANGE

10,000 Hz (max)


KEY FEATURES

Comprehensive monitoring of the mains (utility) supply and auto changeover.

4-line back-lit LCD text display

Five key menu navigation

Support for up to three remote display units

Configurable inputs (8)

Configurable analogue / digital inputs (6)

Configurable outputs (8)

Tier 4 CAN engine support.

Integral PLC editor.

Manual fuel pump control.

Power monitoring (kW h, kVAr, kv Ah, kV Ar h), reverse power protection, kW overload protection.

Mains monitoring and automatic start and changeover to generator power in the event of a mains (utility) out of limits or failure.

Configurable CT positioning.

Data logging facility

Customisable power up text and images

Support for 0-10 V & 4-20mA oil pressure senders.

Related Technical Documents
DSE7320 Auto Start Control Module

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us