Home Products News Contact Us
Home > Products > Generator Sets > Cummins > 50kw 63kva Cummins Diesel Generator Set
50kw 63kva Cummins Diesel Generator Set

50kw 63kva Cummins Diesel Generator Set

Standard Features

1. Engine: DCEC Cummins 4BTA3.9-G2(QC58/67E)

2. Radiator 50℃ max

3. Fans are driven by belt, with safety guard

4. 24V charge alternator

5. Dry type air filter, fuel filter, oil filter

6. Alternator: single bearing alternator

7. IP23, insulation class H/H

8. Main line circuit breaker

9. Standard control panel

10. Absorber

11. Muffler

12. User manual


Diesel Engine Data

Manufacturer:

DCEC Cummins

Model:

4BTA3.9-G2(QC58/67E)

Prime Power:58KW

Standby Power:

64KW 

Rated Speed:

1500(r/min)

Cycle:

4 stroke

Cylinder Arrangement:

4 in line

Displacement:

3.9L

Bore and Stroke:

102*120(mm) 

Compression Ratio:

17.3:1

Governor Type:

Electric

Start battery voltage:

24V DC

Air Intake System

Air Intake System:

Jacket water Aftercooled

Max Intake Restriction:

6.2kPa

Burning Capacity:

3.6m3/min

Air Flow:

158m3/min

Exhaust System

Exhaust Gas Flow:

9.9m3/min

Exhaust Temperature:

560℃ 

Max Back Pressure:

10kPa

Fuel System

Fuel System:

Direct injection

100%( Prime Power) Load:

14.9L/h

50%( Prime Power) Load:

8.1L/h

Oil System

Minimum Required Lube System Capacity:

11L

Oil Consumption:

≤0.4g/kwh

Engine Oil Tank Capacity:

8.1-9.5L

Oil Pressure at Rated RPM:

345kPa

Cooling System

Cooling Way:

Water-cooled
Coolant Capacity - Engine Only:8.3L
Thermostat:82-95℃ 
Max Water Temperature:104℃ 

Alternator Data

Manufacturer:


LEROY SOMER/ 
STAMFORD/ 
SIEMENS/ 
MARATHON/ 
ENGGA / 
KEPU
Excitation Mode:Time harmonic wave excitation
Number of phase and Access Act:3-phase 4-wire
Connecting Type:"Y" type connecting
Alternator Capacity:50kW / 62.5kVA
Alternator Efficiencies:95%
Overload:(PRP)110% load can run 1h
Protection Level:IP22-IP23
Insulation Class, Temperature Rise:H/H
Telephone Influence Factor (TIF):<50
THF:<2%
Voltage Regulation, Steady State:≤±1%
Air Cooling Flow:2.69m3/s
Altitude:≤1000m

Genset Electrical Performance

Voltage Regulation:

≥±5%
Voltage Regulation, Stead State:≤±1%
Sudden Voltage Warp (100% Sudden Reduce):≤+25%
Sudden Voltage Warp (Sudden Increase):≤-20%
Voltage Stable Time (100% Sudden Reduce):≤6S
Voltage Stable Time (Sudden Increase):≤6S
Frequency Regulation, Stead State:≤5%
Frequency Waving:≤1.5%
Sudden Frequency Warp (100% SuddenReduce):≤+12%
Sudden Frequency Warp (Sudden Increase):≤-10%
FrequencyRecoveryTime(100%SuddenReduce):≤5S
FrequencyRecoveryTime(Sudden Increase):≤5S
Options
EngineAlternator
Heater 2KW & 4KWAnti Condensation Heater
Battery Charger 3.5A & 7APermanent Magnet Generator(PMG)
Water SeparatorDrop CT(For Paralleling)
Daily Fuel Tank
Fuel Level Sensor
Control SystemOthers
Remote Control PanelRainproof Type
Auto Transfer Switch (ATS)Soundproof Type
Paralleling SystemTrailer Type
Open Type
Overall SizeWeight
2000(mm)*840(mm)*1370(mm)800(kg)
Cummins open type image.jpg
Soundproof Type
Overall SizeWeight
2400(mm)*1060(mm)*1680(mm)1250(kg)
Cummins 1200 GF Image.png


Standard Control Panel
Cummins 24GFDINGBO Standard Control Panel uses micro processing technique integrating digital, intelligent and network techniques which can carry out functions including auto start/stop, data measure, alarming. The controller uses LCD display, optional Chinese and English display interface with operation easy and reliable. It can be widely used in all types of generator automatic control system for compact structure, advanced circuits, simple connections and high reliability


Auto Module Control Panel
Cummins 24GFAuto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu. Features: 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation. 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. 
Auto Parallel Control Panel
Cummins 24GFThis new automatic parallel system adopts intelligent modules, inserted and folded installed, no need the peripheral relay and logic circuit. The main switch adopts electronic breaker or frame breaker, combined together with the generator, which is very reliable. One generator, one panel. The panel can be used both for singly and parallel. It is only need to parallel generator with such panel when the capability needs to be enlarged in the future.


30kw 38kva Cummins Diesel Generator Set
20KW/25kVA Silent Portable Diesel Generator with Electric Start
10kW Electric Start 2-Cylinder Portable Diesel Generator

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us