Home Products News Contact Us
Home > Applications > Project Cases

Export: Tanzania

Jun. 26, 2017


Export: Tanzania

Manufacturer: Jiangsu Starlight Electricity Equipments Co.,Ltd

Genset power: 200KW, 300KW, 600KW and 800KW

Engine: CCEC Cummins

Alternator: Kepu TFW electric generator

Quantity: 4 sets

Control System: Smartgen HGM6110


Genset Configuration and Parameter

 

Diesel Generator Set Data (200KW)


Set Type:

XG-200GF

Rated Power:

200KW

Rated Capacity:

250KVA

Rated Current:

360A

Rated Voltage:

400V

Rated Frequency:

50Hz

Rated Speed:

1500rpm

Power Factor:

0.8 (Lag)



Engine Data

Manufacturer:

CCEC Cummins

Model:

NT855-GA

Prime Power:

231KW

Standby Power:

254KW



Alternator:

Kepu TFW-200-4A electric generator

Control System:

Smartgen 6110

Dimension:

3000x1020x1750mm

 

Diesel Generator Set Data (300KW)


Set Type:

XG-300GF

Rated Power:

300KW

Rated Capacity:

375KVA

Rated Current:

540A

Rated Voltage:

400V

Rated Frequency:

50Hz

Rated Speed:

1500rpm

Power Factor:

0.8 (Lag)



Engine Data

Manufacturer:

CCEC Cummins

Model:

NTA855-G2A

Prime Power:

312KW

Standby Power:

343KW



Alternator:

Kepu TFW-300-4A electric generator

Control System:

Smartgen 6110

Dimension:

3200x1020x1750mm



Diesel Generator Set Data (600KW)


Set Type:

XG-600GF

Rated Power:

600KW

Rated Capacity:

750KVA

Rated Current:

1080A

Rated Voltage:

400V

Rated Frequency:

50Hz

Rated Speed:

1500rpm

Power Factor:

0.8 (Lag)



Engine Data

Manufacturer:

CCEC Cummins

Model:

KT38-GA

Prime Power:

647KW

Standby Power:

711KW



Alternator:

Kepu TFW-600-4A electric generator

Control System:

Smartgen HGM6110

Dimension:

4400x1800x2200mm

 


Diesel Generator Set Data (800KW)


Set Type:

XG-800GF

Rated Power:

800KW

Rated Capacity:

1000KVA

Rated Current:

1440A

Rated Voltage:

400V

Rated Frequency:

50Hz

Rated Speed:

1500rpm

Power Factor:

0.8 (Lag)



Engine Data

Manufacturer:

CCEC Cummins

Model:

KTA38-G2A

Prime Power:

813KW

Standby Power:

895KW



Alternator:

Kepu TFW-800-4A electric generator

Control System:

Smartgen HGM6110

Dimension:

4600x1800x2200mm



low noise diesel generator set.jpg

Contact Us
  • Adds: No.2 Xingguang Road, Guxi Industrial Park, Taixing, Jiangsu, China.
  • Tel: +86 771 5805 269
  • FAX: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Jiangsu Starlight Electricity Equipment Co., Ltd.All Rights Reserved | Sitemap

Contact Us