Home Products News Contact Us
Home > Supports > Diesel Engine > Perkins Engine Application And 1100 Series Engine Characteristics

Perkins Engine Application And 1100 Series Engine Characteristics

Oct. 18, 2019

Perkins was established in 1932. It is one of the world famous engine production and sales manufacturers with a long history. In 1985, Perkins celebrated engines production of 10,000,000 units. In 2008, Perkins established 400 Series manufacturing facility in Wuxi, China. As the world’s leading manufacturer of Rolls-Royce, Perkins is committed to product quality, environment and economy. By strictly enforcing the ISO9001 and ISO14001 standard, the products have high emission standard, high efficiency, high stability and high reliability and so on characteristics.


Perkins engine is mainly used in five fields including industrial machinery, electric genset, marine, agricultural machinery and lifting equipment. About the proportion, see the pie chart below.


Perkins engine application.jpg


From the chart, we can see that the proportion of industrial machinery and electric genset are relatively large.

In this article, we mainly introduce Perkins 1100 Series (1100A,C,D,F) engine advantage and key model to you.

Power range from 30 to 206KVA


Advantage:


1. 3.3 to 7 litres

2. In-line 3, 4 and 6 cylinders

3. Naturally aspirated, turbocharging, turbo charging with inter-cooling

4. Tropical radiator as standard for high ambient temperatures

5. Most compact engine in its class for easy installation

6. Common components, Simple assembling, Low Inventory

7. Supply mechanical & electronic govern configuration: 1106A-70TAG2/3/4


Perkins engine.jpg


1100 Series (1100 A,C,D) Key Engine Models

 

Engine Model 

Speed 

Genset Prime Power

Engine Output

 Control

Emission


rpm

KW

KVA

KW



1103A-33G

1500 /1800

24

30

28

Mech


1103D-33G2

1500 /1800

25

32

29

Mech

Stage IIIA

1103A-33TG1

1500 /1800

36

45

41

Mech


1103A-33TG2

1500 /1800

48

60

54

Mech


1104D-44TG2

1500 /1800

48

60

54

LCG2

Stage IIIA

1104A-44TG1

1500 /1800

52

65

58

Mech


1104A-44TG2

1500 /1800

64

80

72

Mech


1104C-44TAG1

1500 /1800

64

80

72

LCG2


1104C-44TAG2

1500 /1800

81

101

90

LCG2


1104D-44TG1

1800

57

71

63

LCG2

Tier 3

1104D-E44TG1

1800

65

81

72

ECM

Tier 3

1104D-E44TAG1

1500 / 1800

64

80

73

ECM

Stage IIIA/Tier 3

1104D-E44TAG2

1500 /1800

80

100

92

ECM

Stage IIIA/Tier 3

1206F-E44TTAG2

1800

91

114

109

ECM

Tier 4 Final

1106A-70TG1

1500

108

135

118

Mech


1106A-70TAG2

1500, 1800, 1500 /1800

120

150

131

Mech/LCG2


1206F-E70TTAG3

1800

135

169

151

ECM

Tier 4 Final

1106A-70TAG3

1500, 1800, 1500 /1800

144

180

158

Mech/LCG2


1106A-70TAG4

1500

160

200

174

LCG2


1106D-E70TAG2

1500 /1800

114

142

129

ECM

Stage IIIA/Tier 3

1106D-E70TAG3

1500 /1800

120

150

141

ECM

Stage IIIA/Tier 3

1106D-E70TAG4

1500 /1800

144

180

165

ECM

Stage IIIA/Tier 3

1206F-E70TTAG4

1800

180

225

201

ECM

Tier 4 Final

1106D-E70TAG5

1800

200

250

223

ECM

Tier 3

 

1. 1500/1800 is switchable engine, the power is under 1500rpm;

2. 1500, 1800It means we have both 1500 and 1800 rpm engine, the power in the sheet is under 1500rpm;

 

Note: As we mentioned before, Perkins engines used in electric genset account for a large proportion. Currently, Perkins generator is welcomed by users because of its reliability and high quality.


silent diesel generator set.jpg


If you are also interested in the reliable brand genset, why not take a few minutes to refer to its electrical performance and the related standard?


1) In accordance with the standard GB2820 and ISO8528/3. Conforming to technical requirements for the YD/T502 communication diesel gensets of the post and telecommunication system.

2) In accordance with the provisions of the international standards GB/T2819 ISO8528, IEC34, etc.

3) Rated voltage: 400/230(V)

4) Connection mode: 3-phase, 4-wire

5) Rated Frequency: 50Hz

6) Power factor: 0.8(Lag)

7) Radio interference suppression: comply with the provisions of VDE0875-N Class and GB2820 regulations.

8) Accord with the rated output power of generator set.

9) Altitude is less than 1,000m.

10) Environmental temperature 0 degree ~ 40 degree.

11) Relative air humidity of 60%.

Contact Us
  • Add.: Room 601, Laboratory Building, No.2 Gaohua Road, Nanning, Guangxi, China.
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Guangxi Dingbo Power Equipment Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

seokeywords:

test2
Contact Us